In radiological measurement applications, the distance between the potentially contaminated area and the control station is typically several kilometers for safety reasons. In addition, in the event of large-scale disasters, reliable communication infrastructure such as mobile networks cannot be assumed. The sensor system must therefore provide its own data connections.
System Overview
The implementation was carried out in cooperation with MIRION engineers within one day shortly before the test flights with the customer. The system assessment was carried out at two sites in France.
Appraisal of results
The range test shows that the expected range of 1 km can be easily achieved in and out of line of sight.
In visual contact conditions, the communication range was at least 3.8 km.
The average delay was less than 1s. During the test with obstacles, the UAV flew about 1,7 km without data transmission. As soon as the connection was restored, the intermediate data was transmitted at maximum data rate.